Product Details:
Contact Now
Chat Now
|
Capacity: | 450L | Chamber Size: | 652*700*1000mm |
---|---|---|---|
Machine Size: | 1360*1400*2060mm | Net Weight: | 1150kg |
Working Temp.: | 138℃ | Working Press.: | 0.25Mpa |
Ultimate Vacuum: | -96KPa | Door Structure: | Sliding-Door |
Steam Generator: | Build-In Steam Generator | Number Of Doors: | Double Door |
Highlight: | 450l horizontal autoclave sterilizer,450l horizontal steam sterilizer autoclave,double door horizontal autoclave sterilizer |
This autoclave machine horizontal uses saturated steam as the sterilization medium, which would completely penetrate into the surface of the articles through pulsating vacuum, and all the microorganisms and their spores would be killed by it under high pressure. It is the most reliable and effective method in physical sterilization. Pulsating vacuum exhaust eliminates the influence of cold air on temperature, finally, the sterilizing articles are dried by vacuum dehumidification combined with a jacket.
Model | STH-RV450S(D) | Maximum Working Temperature | 139°C |
Chamber(WxH)(mm) | 652x700 | Maximum Working Pressure | 0.25MPa |
ChamberDepth(mm) | 1000 | Vacuum Leakage Rale | ≤0.13KPa/min |
Volume(m3) | 450 | Ultimate Vacuum | -97KPa |
Overall Size Lx Wx H(mm) | 1300x1350x1950 | Opening Pressure for Inner Chamber's Safety Valve | 0.28MPa |
Weight(Kg) | 1150 | Opening Pressure for Jacket's Safety Valve | 0.28MPa |
c Steam.Consumption(Kg/C) | 30 | Precision of Sterilization Temperature Control | 0~2°C |
Power Supply | 380V, 50HZ | Temperature Uniformity | ±1°C |
Power | 2KW + 36KW | Negative Pressure Pulsation | Amplitude -80~0KPa, |
Designed Pressure of Inner Chamber | -0.1~0.3MPa | Vacuum Amplitude and Times | Times 1~99 |
Designed Pressure of Jacket | 0.3MPa | Times of Pulses Across Pressure | Amplitude -80~80KPa, Times 1 |
Designed Temperature | 150°C | Times of Positive Pressure Pulses | 1~3 |
Advanced Lifting Door System | Automatic Sliding Door Autoclave
Motor-driven chain mechanism with anti-pinch function provides enhanced operational and installation space.
Removable racks allow for convenient loading and unloading of various articles.
Double lifting doors feature pressure safety interlocks; liquid sterilization program includes an additional temperature safety interlock for extra protection.
The two doors are fully interlocked to ensure operator safety during use.
Superior Sealing System | Rectangular Chamber Autoclave
Automatic sealing achieved through inflation pressure driving a high-quality, tear-resistant silicone rubber circular hollow sealing ring.
Special anti-wear surface coating ensures smooth operation and improved sealing efficiency.
Service life up to 1,500 cycles, significantly extending maintenance intervals.
Chamber and Structural Design | Pulse Vacuum Sterilizer
Rectangular chamber with European ring-type jacket and reinforcing ribs for durability.
Getinge structure sealing groove welded onto the jacket for superior strength and sealing.
Suitable for large hospital CSSD and pharmaceutical production.
Intelligent Control System | Siemens PLC Control
Fully automated sterilization process with Siemens PLC and color touchscreen interface.
Real-time display of operation status, temperature, pressure, and time.
Supports custom cycle programming for versatile applications.
Traceability and Communication | Hospital Sterilization Traceability System
Communication interface compatible with CSSD traceability systems.
Offers communication protocols for seamless integration with third-party hospital systems.
Versatile Sterilization Programs | Multi-purpose Vacuum Autoclave
Built-in sterilization programs for garments, surgical instruments, rubber, liquids, culture media, and biological waste.
Supports BD test, vacuum leakage test, and validation protocols for sterilization assurance.
Comprehensive Data Logging | Paperless Recorder Autoclave
Real-time printing via built-in micro-needle printer.
Paperless data recorder for long-term electronic data storage and retrieval.
Optional Smart Maintenance System | Remote Monitoring Module
Optional remote diagnostics and software updates for intelligent maintenance.
Enables real-time system health monitoring and remote technical support.
Independent Steam Inlet Design (Optional) | Contamination Prevention
Steam bypasses the jacket to prevent contamination from carbon steel pipelines.
Prevents drying inefficiencies caused by jacket pressure drops during sterilization.
Premium Pipeline and Component Integration | High-Quality Sterilization Components
Pipeline system built from stainless steel sanitary tubing with clamp joints, welded by automatic pipe welder.
Uses German GEMÜ angle seat valves, Taiwan Airtac solenoid valves, and German SPECK vacuum pump for reliable performance.
Optional Water-Saving & Noise Reduction | Energy Efficient Vacuum Autoclave
Reduces vacuum pump circulating water consumption by up to 30%.
Significantly lowers operational noise, ideal for hospital environments.
Optional Automatic Drain System | Steam Quality Assurance
Automatically detects temperature and pressure in the jacket and chamber for precise auto-draining.
Includes automatic discharge temperature control (≤ 55°C) for safe condensate disposal.
High-Efficiency Air Filtration | Sterile Working Environment
Equipped with a 0.22 μm HEPA air filter, achieving 99.97% sterilization efficiency.
Ensures a clean and contamination-free working environment after sterilization cycles.
Horizontal Autoclave Machine Pricing: As the source factory, we eliminate middleman costs, providing global clients cost-effective sterilization solutions directly.
Efficient Direct Support: Our service team ensures rapid and efficient communication and support, handled entirely in-house from production to after-sales.
Custom Autoclave Solutions: Leveraging strong technical expertise, we offer both standard models and fully customized equipment tailored to specific structural, functional, or control requirements.
Certified Medical Autoclave Quality & Safety: Every device undergoes strict quality control and holds international certifications (including CE, ISO 13485, ISO 9001), guaranteeing safety, stability, and long-term reliability.
Contact Person: Miss. Kira Tang
Tel: 008615665436825